A flat RCC terrace is never actually flat on a well-built site. The slab is cast dead level structurally, and slope is then formed above it using a screed of lean concrete or brickbat coba, graded towards rainwater outlets so that no pocket of standing water can sit on the roof for days. A common target is a slope of about 1 in 100 to 1 in 60 running towards the drain mouths, with the screed thickness varying from a thin edge at the outlet to a thicker high point at the ridge or centre of each bay. Getting this slope wrong is one of the most common causes of terrace leakage complaints years after handover, because ponding water eventually finds its way through even a good waterproofing membrane.

Waterproofing itself is applied over the structural slab and under or within the slope screed depending on the system chosen. Brickbat coba with a layer of broken brick bats bedded in cement mortar, then rendered and finished with China mosaic or tiles, remains common in residential Indian construction because it is economical and gives some thermal insulation. Modern alternatives include APP or SBS modified bitumen membranes torched or self-adhered to a primed surface, and liquid-applied polyurethane or acrylic coatings reinforced with fabric at joints and upstands. Whatever system is used, waterproofing must turn up at least 150 to 300 mm at every parapet, upstand and pipe penetration, because the junction between vertical and horizontal surfaces is where leaks almost always start, not the open flat area.

Parapets, the low walls running around the terrace edge, serve both a safety function under the National Building Code 2016 and a water-management function by containing roof flow towards planned outlets rather than letting it sheet off the edge. A coping, usually precast RCC or stone, is laid on top of the parapet with a slight outward slope and a drip groove on the underside so rainwater does not run back down the face of the parapet and stain or dampen it. Rainwater outlets, commonly called rain water pipes or down takes, need to be sized and spaced to handle the roof's catchment area without overflow, and their mouths are kept slightly lower than the general terrace level with a strainer or jali to stop leaves and debris from choking the pipe.

A frequent site mistake is applying waterproofing and finishing tiles before the parapet and upstand junctions are properly treated, or before a water-ponding test is done. Good practice is to flood the terrace with roughly 50 mm of water after waterproofing and before the protective screed or tiling goes down, holding it for at least 24 to 48 hours and checking the ceiling below for any damp patch. Only after this test passes should the protective screed, China mosaic or tiling be laid, because any leak found afterwards means breaking finished work to trace and repair it.

Typical terrace slope

1 in 100 to 1 in 60

Waterproofing upturn at parapet

150-300 mm

Ponding test duration

24-48 hours

Flood test water depth

~50 mm

Remember on site

  • Terrace slope towards outlets (roughly 1 in 100 to 1 in 60) prevents ponding, the main cause of roof leaks
  • Waterproofing must turn up 150-300 mm at every parapet, upstand and pipe penetration
  • Parapet coping needs outward slope and a drip groove; rainwater outlets need adequate size, spacing and strainers
  • Flood-test the terrace for 24-48 hours before laying the protective screed or tiling

Check yourself

Why is slope formed on an RCC terrace using a screed rather than casting the slab itself sloped?

What is the main risk of standing water, or ponding, on a terrace?

Where do roof leaks most commonly originate on a well-waterproofed terrace?

What is 'brickbat coba'?

What is the purpose of the drip groove under a parapet coping?

Before laying the protective screed or tiling over a waterproofed terrace, what test should be carried out?

What is the function of a parapet wall on a terrace, besides safety?

Why are rainwater outlet mouths fitted with a strainer or jali?

What is a key difference between brickbat coba and a liquid-applied polyurethane waterproofing system?

What commonly happens if waterproofing and finishing are completed before parapet and upstand junctions are properly treated?