Sign in to save & sync
Sign in

Water tank / sump capacity

Occupants, daily water needs, reserve days and overhead storage

Explanation in

Usable sump storage required

1,080

L

Domestic water
540 L/day
Garden / car washing / other
0 / 0 / 0 L/day
Total daily demand
540 L/day
30-day demand
16.2 kL (30-day assumption)
Usable sump volume
1.08 m³
Overhead tank
270 L usable
Overhead autonomy
12 hours at average use

How we got this

  1. 1

    Daily domestic water

    Formula
    Occupants × litres/person/day
    Your numbers
    4 × 135
    Answer
    540 L/day
    Why
    Planning demand is not drinking water alone.
  2. 2

    Add separate uses

    Formula
    Domestic + garden + cars × wash water + other
    Your numbers
    540 + 0 + 0 + 0
    Answer
    540 L/day
  3. 3

    Sump reserve

    Formula
    Daily demand × reserve days
    Your numbers
    540 × 2
    Answer
    1,080 L usable
    Why
    Add freeboard and unusable bottom water when selecting physical dimensions.
  4. 4

    Overhead tank

    Formula
    Daily demand × overhead share / 100
    Your numbers
    540 × 50 / 100
    Answer
    270 L usable
    Why
    Check peak demand, pumping cycles and incoming supply separately.

The theory behind it

Method used: Daily demand × selected reserve days; overhead storage calculated separately

Count occupants, multiply by a selected daily allowance, then add separately justified outdoor or other uses. Storage bridges the chosen period without incoming supply. The overhead tank supplies gravity flow between pump cycles; it is not automatically extra reserve.

Assumptions used

  • •135 L/person/day is a selected residential planning rate, not a guarantee of actual consumption or a universal local approval requirement. BIS Table 48 gives conditional ranges of 100–135 and 150–200 L/person/day; confirm the applicable local requirement.
  • •Domestic demand covers drinking, cooking, bathing, flushing, laundry, utensils and household cleaning together. Do not add these again on top of the per-person allowance.
  • •Gardening, car washing and other uses are entered separately only when not already covered. Car-wash water depends on hose/bucket/equipment and is not a fixed standard.
  • •Reserve days and overhead-tank share are editable supply-reliability assumptions, not mandated NBC storage ratios. Sump reserve and overhead storage are reported separately, not counted twice as days of autonomy.
  • •Fire reserve, pools, commercial use, construction water and municipal network losses are excluded. Required fire water must be separately designed and protected from domestic drawdown.
  • •Choose occupancy for full expected use, including regular residents; add visitors' demand under other daily uses. Use meter readings to refine the per-person allowance.

Codes & references

  • BIS SP 73:2023, Table 48 — residential demand depends on population, full flushing, housing category and water availability. https://www.bis.gov.in/wp-content/uploads/2024/02/SP-732023-Standardized-Development-and-Building-Regulations-2023.pdf
  • NBC 2016 Part 9 Section 1 / IS 1172 — confirm local water supply and storage requirements.
History

Estimates for guidance only. Confirm quantities with your site engineer.

© 2026 SiteMate. All rights reserved.