Sign in to save & sync
Sign in

Industrial shed / PEB steel tonnage

Portal frames, purlins, girts and bracing for a gable shed

Explanation in

Total steel

0

t

Frames
0 nos
Columns
0 t (0 US ton)
Rafters
0 t (0 US ton)
Purlins
0 lines · 0 t (0 US ton)
Side girts
0 lines per wall · 0 t (0 US ton)
Steel per floor area
0 kg/m² (0 kg/ft²)
Ridge height
0 m (0 ft)

How we got this

  1. 1

    Frames

    Formula
    Length ÷ bay + 1
    Your numbers
    0 ÷ 0 + 1
    Answer
    0 frames
  2. 2

    Rafter length

    Formula
    √((span/2)² + rise²), rise = (span/2) ÷ n
    Your numbers
    √(0² + 0²)
    Answer
    0 m (0 ft)
  3. 3

    Columns

    Formula
    frames × 2 × eave × kg/m
    Your numbers
    0 × 2 × 0 × 0
    Answer
    0 kg (0 lb)
  4. 4

    Rafters

    Formula
    frames × 2 × rafter × kg/m
    Your numbers
    0 × 2 × 0 × 0
    Answer
    0 kg (0 lb)
  5. 5

    Purlins

    Formula
    lines × length × kg/m
    Your numbers
    0 × 0 × 0
    Answer
    0 kg (0 lb)
  6. 6

    Girts

    Formula
    lines × perimeter × kg/m
    Your numbers
    0 × 2 × (0 + 0) × 0
    Answer
    0 kg (0 lb)
  7. 7

    Add bracing & connections

    Formula
    Σ × (1 + %)
    Your numbers
    0 × 1
    Answer
    0 t (0 US ton)

The theory behind it

Method used: Member-by-member take-off

A gable shed is a row of portal frames (two columns + two rafters) placed at the bay spacing. Purlins span frame to frame carrying the roof sheets; girts do the same on the side walls. Steel = number of each member × its length × its weight per metre. Bracing, cleats, base plates and bolts are added as a percentage.

Assumptions used

  • •Section weights come from your design (ISMB / built-up tapered members in a PEB). Typical PEB sheds weigh 25–45 kg per m² of floor.
  • •Gable end frames taken the same as interior frames (conservative).
  • •Girts run along both long walls and both gable walls up to eave height.

Codes & references

  • IS 800:2007 — General construction in steel
  • IS 875 (Part 1–3) — Dead, live and wind loads
  • MBMA / IS 801 — Cold-formed purlins
History

Estimates for guidance only. Confirm quantities with your site engineer.