Sign in to save & sync
Sign in

Column jacketing (micro-concrete)

Retrofitting jacket volume and micro-concrete bags

Explanation in

Micro-concrete bags

0

bags

Jacket section
0 m² (0 ft²)
Jacket volume
0 m³ (0 ft³)
New size
0 mm (0 in) × 0 mm (0 in)

How we got this

  1. 1

    Section

    Formula
    (b+2t)(d+2t) − b·d
    Your numbers
    (0)(0) − 0×0
    Answer
    0 m² (0 ft²)
  2. 2

    Volume

    Formula
    Section × H × nos
    Your numbers
    0 × 0 × 0
    Answer
    0 m³ (0 ft³)
  3. 3

    Bags

    Formula
    Litres × 1.05 ÷ yield
    Your numbers
    0 × 1.05 ÷ 0
    Answer
    0

Short forms used above

nos
— Numbers (count)

The theory behind it

Method used: Outer section − existing section

An RC jacket wraps the old column on all sides. Jacket volume = (b + 2t)(d + 2t) − b × d, times height. Free-flowing micro-concrete fills the thin gap around new bars.

Assumptions used

  • •Minimum jacket thickness 100 mm per IS 15988.
  • •Yield per bag from the product data sheet.

Codes & references

  • IS 15988:2013 — Seismic evaluation and strengthening of RC buildings
History

Estimates for guidance only. Confirm quantities with your site engineer.