Base plates & anchor bolts

Plate steel, anchor bolts and grout for column bases

Explanation in

Plate steel

0

kg

Anchor bolts
0 nos · 0 kg (0 lb)
Non-shrink grout
0 m³ (0 ft³) · ≈ 0 bags of 25 kg

How we got this

  1. 1

    Plate

    Formula
    L × B × t × 7850 × n
    Your numbers
    0 × 0 × 0 × 7850 × 0
    Answer
    0 kg (0 lb)
  2. 2

    Bolts

    Formula
    d²/162 × L × nos
    Your numbers
    0²/162 × 0 × 0
    Answer
    0 kg (0 lb)
  3. 3

    Grout

    Formula
    (L+0.1)(B+0.1) × t × n
    Your numbers
    0.1 × 0.1 × 0 × 0
    Answer
    0 m³ (0 ft³)
    Why
    Grout density ≈ 2100 kg/m³.

Short forms used above

d
— Bar diameter (mm)
Written as 9d, 2d, 50d — multiples of the bar's own diameter.
d²/162
— Weight of steel per metre
π/4 × d² × 7850 kg/m³ ÷ 10⁶ = d²/162.2 kg/m. 12 mm → 144/162 = 0.889 kg/m.
nos
— Numbers (count)
m³
— Cubic metre (volume)
kg/m³
— Kilograms per cubic metre (density)

The theory behind it

Method used: Volume × 7850 kg/m³

Plate weight = length × width × thickness × 7850. Anchor bolt weight = d² ÷ 162 kg per metre (d in mm) × length. Non-shrink grout fills the gap between plate and pedestal top, with ~50 mm extra all round.

Assumptions used

  • •Nuts, washers and levelling nuts not weighed.
  • •Grout area = (L + 100) × (B + 100) mm per base.

Codes & references

  • IS 800:2007 Cl. 7.4 — Column bases
  • IS 5624 — Foundation bolts
History

Estimates for guidance only. Confirm quantities with your site engineer.